Laminar Air Flow Cabinet |
| |
We offer a comprehensive range of high performance horizontal, vertical Laminar Flow Clean Air Cabinets. It has a modular construction, combining aesthetic appeal with functional utility and efficiency. These are designed to meet the filtration, illumination, noise & vibration requirements, providing air to meet class 100 (class I) conditions, to the extent applicable.
True Laminar Airflow
Unidirectional airflow moving along parallel flow lines at a constant velocity minimizes air turbulence within the work area.
Optimum Volume Of Air Creates A Safe Environment
Selection of specific motor/blower, HEPA filter(s), materials, electronics, work space and plenum sizes - creates a crucial combination of elements providing an optimal air volume for personnel, product, and environmental protection.
|
| |
More details... |
| |
|
 |
Pharmacy Isolator |
| |
Jindal isolation systems provide inherently superior sterility compared to open front clean air devices such as laminar flow clean benches and Class II biological safety cabinets. USP797 guidelines specify that isolators may be situated in an area subject to less severe environmental controls compared with open front clean air devices. The pharmacy isolators are also for H1N1 applications. The pharmacy isolators are a cost-effective solution especially for lower-volume pharmacies. They reduce operating and renovation costs, take up less space, and are easier to maintain. The negative pressure, recirculating model is suitable for work involving hazardous materials, antineoplastic, or cytotoxic compounding applications.
The work zone and pass-thru interchange are under negative pressure to the room in order to maintain operator protection.
When hazardous drugs compounds have the potential to volatilize, the negative pressure, recirculating isolator should be selected. |
| |
More details... |
| |
|
| |
|
|
|
 |
Biological safety Cabinet |
| |
Jindal bio safety cabinets are innovatively designed for a brighter, quieter and more comfortable environment. Our Biological Safety Cabinet offers a comprehensive range of high performance, modular in construction combining aesthetic appeal with functional utility and efficiency. Jindal Biological Safety Cabinet complies with the guidelines laid down by U.S. National Institute of Health, and the specifications of British Standard 5726 — Appendix A for class II Biological Safety Cabinets.
In addition to normal feature of Vertical Laminar Flow, It is provided with following unique features:
• Re-Circulation of Air – offering highest level of cleanliness.
• Sliding Sash – renders unit convertible for use as a conventional
vertical laminar down flow clean air work station.
• Filtered Exhaust – protects ambient environment, and avoids build up,
air borne particle.
• Supplementary Air Barrier – prevents contamination through make up
air.
• Built in U.V. Germicidal light – facilitates sterilization of working area
before and after use.
• Cock – for gas, air or vacuum, (only 1 no.) is provided.
• Static Pressure Manometer – is used for monitoring the HEPA filters. |
| |
More details... |
| |
|
 |
Fume Hood |
| |
The fume hood is an important safety device in any laboratory. Fume Hoods are recommended for exhaust from the hood working area, of gases, vapour, toxic particles, odour to improve working environment of people who regularly handle toxic substances. These reduce personal exposures and odour level in the laboratory. These are designed to exhaust toxic or otherwise harmful vapours etc., for protecting laboratory personnel & equipments.
A motor-blower exhaust system generates negative pressure within the hood, extracting the contaminated air from the work area and expelling it into the atmosphere and preventing the fumes from escaping into the room. These are recommended for various laboratories like Bio-Chemistry, Pharmaceutical units, printed circuit etching/cleaning etc. These are capable of handling corrosive fumes of sulphuric and hydrochloric acids etc. If work-area walls are lead-lined (Optional), it can be effectively used for Radio-Isotopic applications. |
| |
More details... |
| |
|
| |
|
|