Sample Concentrator SMI-SC200-2
Home ≫Heating & Environment>Sample Concentrators>Sample Concentrator SMI-SC200-2
Description
The JINDAL SC200-2 nitrogen concentrator is mainly used for enrichment of large-volume samples or preparations (such as drug screening, hormone analysis, liquid phase, and mass spectrometry in the analysis of sample preparation). Working principle: the nitrogen enters the heated surface of the sample and makes the solvent evaporate and separate rapidly, thereby reaching the sample enrichment purpose without oxygen, keeping the sample purer. A nitrogen concentrator instrument can concentrate dozens of samples simultaneously, saving time and being more efficient than a rotary evaporation instrument.
Latest Ergonomic Features:
- Synchronously working with heating by a dry bath in the bottom and nitrogen blowing on the surface accelerates liquid evaporation and sample concentration.
- The position of the gas needle in the air cavity can be adjusted to suit different types of tubes.
- The height of the air cavity can be adjusted. The length of a standard gas needle is 150 mm.
- The gas needle is controlled independently. Separate blowing of each needle and flow regulating of each needle are available to avoid gas waste
- The entire equipment can be put into a ventilation cabinet when the concentration of samples in toxic solvents takes place.
- Built-in overheat protection, automatic fault detection, and fault beep alarm devices
- LEDs display immediate temperature and diminishing time. Operation is simple and convenient.
- Standard-configured air cavity and adjustable bracket.
Technical Data:
- Temp. Control Range: R.T.+5℃ ~150℃
- Temp. Setting Range: 5℃ ~150℃
- Temp. Stability@40~100℃: ≤±0.5℃
- Temp. Stability@100~150℃: ≤±1℃
- Block Temp. Uniformity@100℃: ≤±0.5℃
- Block Temp. Uniformity@150℃: ≤±1 ℃
- Temp. Display Accuracy: 0.1℃
- Heating Speed: ≤30min (40℃ to 150℃)
- Time Range: 1min ~99h59min or continuous
- Needle Plate Max. Lift Stroke: 285mm
- Gas-in Joint Outer Diameter: Φ7mm
- Nitrogen Pressure: ≤0.1MPa
- Nitrogen Flow Rate: 0 ~10L/min
- Needle Length: 150mm
- Sample Capacity: 2 standard blocks
- Voltage: AC 220V / AC 110V, 50/60Hz
- Power: 400W
- Dimension (WxDxH): 200 x 260 x 525mm
- Net Weight: 6.1kgs
Optional Blocks & Flow Regulating Valve:
Cat# | Spec | Dia. Of hole | Hole bottom shape | Block dimension |
DT01A | 6 mm x 12 | 6.5 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT02A | 7 mm x 12 | 7.5 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT03A | 10 mm x 12 | 10.5 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT04A | 12 mm x 12 | 12.5 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT05A | 13 mm x 12 | 13.5 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT06 | 15 mm x 12 | 15.5 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT07 | 16 mm x 12 | 16.5 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT08 | 19 mm x 12 | 19.5 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT09 | 20 mm x 6 | 20.5 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT10 | 26 mm x 6 | 26.5 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT11 | 28 mm x 4 | 28.5 mm | Flat bottom | 95.5 x 76.5 x 50 mm |
DT12 | 40 mm x 2 | 40.5 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT13A | 0.5 ml x 12 | 8 mm | Cone bottom | 95.5 x 76.5 x 50 mm |
DT14A | 1.5 ml x 12 | 10.8 mm | Cone bottom | 95.5 x 76.5 x 50 mm |
DT15A | 2.0 ml x 12 | 10.8 mm | Round bottom | 95.5 x 76.5 x 50 mm |
DT16A | 0.2 ml x 12 | 6.1 mm | Cone bottom | 95.5 x 76.5 x 50 mm |
DT19 | Customized | Customized | Customized | Customized |