Home ≫Clean Air >Biosafety Cabinets >Class II Type A2 Biological Safety Cabinet SMI-163AB
JINDAL Biological Safety Cabinet Class II type A2 is vertical designed with Floor standing model stand with castors to protect the lab staff, the environment and sensitive work processes in which biological agents are used. The safety cabinet offers a high level of contamination protection, based on two advanced HEPA filters operating at an efficiency of 99.9999% with a particle count of 0.3 μm & an airflow pattern of 70% recirculation and 30% exhaust. Stand height is 28 inch.
The Cabinet consist work bench construction with heavy duty support stand made of mild steel with polyurethane paint coated for ensures durability, long life & rust-free performance. Antimicrobial coating on all external sides .The Cabinet outer body is made of 18-guage electro galvanized steel with epoxy power coated finishing. The interior of the cabinet including the work area and side panels and back panel are made of 16-guage stainless steel 304G with 4B finishing. Gas and vacuum fixtures on side panels and 15 amp plug socket on back panel.
The Cabinet is equipped with a smart, safe and user friendly color touch-screen control system that protects the operator and provides alerts for periodic maintenance actions and parts’ replacement. The cabinet has safety reasons for the user & the environment and accessories is supplied with each cabinet Foot operated burner, canopy to connect external duct.
The cabinet is preserved for safety reasons for the user and the environment. The BIO safety cabinet has consistent and reliable down flow velocity across the supply HEPA filter over the life of the cabinet. The cabinet has a pressure sensor for detect pressure drop across the supply filter, rather than at just one point across the down flow.
The system also has a programmable “standby” mode that shuts down all unnecessary electricity consumption and sets vital components at the required safety level. The safety cabinet has automatically dual DC motor adjusts airflow speed without the use of a damper for ensure continuous safe working conditions, even without maintenance adjustments. Transparent toughened safety glass sash with Conventional weight counter balance system.
Specs/Model | SMI-163AB-3 | SMI-163AB-4 | SMI-163AB-6 |
External Size (W X D X H) | 850 X 775 X 2295 mm | 1380 X 775 X 2295 mm | 1870 X 775 X 2295 mm |
Internal Size (W X D x H) | 900 X 630 X 780 mm | 1150 X 630 X 650 mm | 1690 X 610 X 610mm |
Working Area Height | 500mm | 500mm | 500mm |
Maximum Front Sash Opening | 520mm | 520mm | 520mm |
Tested Front Sash Opening | 200mm | 200mm | 200mm |
Production/ Test Standard | CE / In accordance with EN12469 | CE / In accordance with EN12469 | CE / In accordance with EN12469 |
Air Flow Volume (Inflow) | 350 CFM | 350 CFM | 350CFM |
Air Flow Volume (Downflow) | 400 CFM | 400CFM | 712 CFM |
Air Flow Volume (Exhaust ) | 250 CFM | 250 CMF | 488 CFM |
Downflow Velocity | 0.40m/s, 80FPM | 0.40m/s, 80FPM | 0.40m/s, 80FPM |
Inflow Velocity | 0.5m/s, 100FPM | 0.5m/s, 100FPM | 0.5m/s, 100FPM |
Front Window 10” sash open | 5mm thick polycarbonate sheet | 5mm thick polycarbonate sheet | 5mm thick polycarbonate sheet |
Filter | HEPA/ULPA Two, 99.9999% efficiency at a particle count of 0.3um, with pressure drop of 12 mm WG | HEPA/ULPA Two, 99.9999% efficiency at a particle count of 0.3um, with pressure drop of 12 mm WG | HEPA/ULPA Two, 99.9999% efficiency at a particle count of 0.3um, with filter pressure drop of 12 mm WG |
Noise Level | <50dB | <50dB | <50dB |
Internal fluorescent light | >1000Lux Eco-friendly | >1000Lux Eco-friendly | >1000Lux Eco-friendly |
Display | Digital Display with Pressure Gauge Differential | Digital Display with Pressure Gauge Differential | Digital Display with Pressure Gauge Differential |
Power Sockets | Two (15/5 Amp) | Two (15/5 Amp) | Two (15/5 Amp) |
UV Light | 30W ; 254nm | 30W ; 254nm | 40W ; 254nm |
Audio-Visual Alarms | Deviation in airflow velocity, Filter replacement, sash position, UV life timer | Deviation in airflow velocity, Filter replacement, sash position, UV life timer | Deviation in airflow velocity, Filter replacement, sash position, UV life timer |
Taps | Water Tap : 1 Gas Tap : 1 Vacuum/Air Tap : 1 | Water Tap : 1 Gas Tap : 1 Vacuum/Air Tap : 1 | Water Tap : 1 Gas Tap : 1 Vacuum/Air Tap : 1 |