Rotary Evaporator (New Modular Design) SMI-RVE-009NMD12
Home ≫Heating & Environment > Rotary Evaporator > Rotary Evaporator (New Modular Design) SMI-RVE-009NMD12
Features
- Evaporating flask with an ejector, convenient to remove
- 5L water and oil bath dual-purpose heating pot, heating temperature can reach 200°C, easy to switch between water and oil bath heating modes
- Locking facility for set parameters temperature and rotation
- Patented technology condenser, high recovery rate, condensing effect outstanding
- Built-in over-temperature protection power cut off
Technical Specification
Model | SMI-RVE-009NMD12 |
Evaporating Flask | 1L(NS 29/32, 18300120 ) |
Receiving Flask | 1L(KS 35/20, 18300110) |
Controller | Microprocessor control |
Temperature Display | Digital |
Rotating Speed | 10-280rpm |
Temp. Range | Ambient to 200°C |
Temp. Accuracy | Water bath: ±1°C; Oil bath: ±3°C |
Lift | Motor |
Stroke Height | 150mm |
Timing Range | 1-999min |
Motor | DC brushless motor |
Heating Power | 1300 W |
Stroke Displacement | Automatic 150mm |
Protection Class | IP20 |
Distillation time | Pre-programmable |
Interface | USB |
Power | 1400W |
Power Supply | AC110/220-240V±10%, 50/60Hz(Customizable) |
External Size(W*D*H) | 465*457*583 mm |
Package Size(W*D*H) | 640*1100*650mm |
Net Weight | 15kg |
Gross Weight | 36kg |
Single joint size accommodate | 50 ml to 2000 ml |
Standard Accessory | 1L Evaporating flask*1, 1L Receiving flask*1, PTFE valves |
Optional Accessory | Vacuum pump, Recirculating chiller |
Vacuum Controller SMI-RVE-009NMD12VC
The vacuum controller serves as a device for labs to display, adjust and control the degree of vacuum in vacuum systems. It generally constitutes the vacuum control system of rotary evaporator along with vacuum pump, which enables repeatable distillation experiment and recovery of many kinds of solvents in an efficient and automatic manner.
Features
- A wide range of measurement and control, 1-1,000mbar
- Two control modes of single-point control and programmed control available for choice as needed
- Can store up to 5 programs, each containing up to 5 segments of programming control
- All parts in contact with vapor or liquid are made of PTFE, ceramics or other high-performance materials and can effectively resist corrosion caused by organic solvents, water, acid and alkali
- A built-in vent valve can feed inert gas into system equipment
- One-stroke decompression allows easy installation and dismantling of vacuum system
- Can be connected with pump power control for temporary shutdown of pump power supply after reaching stable degree of vacuum for energy conservation and environmental protection. Can also be operated in the normally open statue of pump
Technical Specification
Specifications | SMI-RVE-009NMD12VC |
Vacuum setting range | 1-1000mbar |
Vacuum measurement range | 1-1000mbar |
Control operation mode | Single-point control mode, Programmed control mode |
Control program | Can store up to 5 programs, each containing 5-step control (capable to set the degree of vacuum and time) |
Setting method | Touch screen setting |
Display | 6” digital touch screen |
Sensor overload pressure | 1,500mbar |
Operation | Knobs |
Measuring accuracy | ± 2 mbar (±1 digit) |
Connector diameter | 8mm |
Venting option | Manual |
Materials in contact with vapor | PTFE, PP, silicone and ceramics |
Protection class | IP20 |
Compatible conditions with vacuum pump | power of 50Hz vacuum pump ≤400W power of 60Hz vacuum pump ≤500W |
Overall dimensions W×D×H | 189×207×193mm |
Power supply | 110—240V,50Hz/60Hz |
Operating environment | 10℃~40℃ ≤80%RH |
Vacuum Pump SMI-RVE-009NMD12VP
Specification
- Ultimate vacuum:7 mbar
- PTFE chemically resistant diaphragm pump
- Work mode: continuous operation
- Nozzle size: 8mm
- Power: 95W
- Motor speed:1450rpm
- Vacuums pump capacity: 2m3 /h
Seals and other accessories
Vacuum regulator/moisture trap
In use of control small volume, installed in a vacuum between DVR480 and vacuum system. Material: PVDF, PTFE, ABS, Borosilicate Glass, Stainless Steel
Re-circulation Chiller SMI-RVE-009NMD12C
Features & Advantages
- Small size-requires an installation space of 50 x 23 x 50mm(L*B*H).
- Can be installed directly on desktop, under lab bench, or in a fume hood, saving valuable space.
- Environmentally friendly refrigerant producing no-toxic pollution.
- Intuitive liquid level window for easy monitoring of liquid level in storage tank.
- Air cooled cooling
- Water tank is set to protect the overflow port and drain port, which is convenient for filling-in and draining-out liquid.
- Noise free operation
- Pump pressure and flow can be automatically adjusted according to load change.
- Adopt PID temperature control technology which greatly improves temperature stability.
Specification
Specifications | SMI-RVE-009NMD12C |
Temperature Range | -10℃ to Ambient Temp. |
Temperature Display | LED digital, Accuracy 0.1℃ |
Temperature Stability | ±0.02 K |
Cooling /Refrigerating Capacity | 250W |
Pump Pressure | 0.0005bar |
Pump Suction | 0.2bar |
Flow rate | 7Lit/ min |
Coolant Capacity | 4L |
Cooling Water Tubing | Silicone |
Communication Interface | Optional RS232/485 |
Low-level Alarm | Optional |
Heating Function | Optional |
Dimensions ( W x D x H ) | 220x420x495(mm) |
Operating Environment | 5-32℃ |
Outer Connected Dimension | Standard 8mm insulation tube |
Power supply | 220-240V/50Hz |
Application
- Ideal for cooling of rotary evaporator (3L small rotary steaming), reaction kettle system, bioreactor and so forth.
- Compatible with distillation system, concentrator, extractor, condensing reflux device, etc.
- For analytical devices such as ultrasonic disrupting instrument, continuous flow analyzer.
Components
- Low Temperature Circulator. Silicone Insulation Tube 1.8m*2 pcs. ,Connector, Warranty Card, Operators Manual
Product Brochure
Product Brochure Link here