S.M. Scientific Instruments (P) LTD

Smart Mixer SMI-MIX-3000

Home ≫Heating & Environment>Smart Mixer>Smart Mixer SMI-MIX-3000

Smart Mixer SMI-MIX-3000

CLICK TO SCAN

Description

The JINDAL smart mixer SMI-MIX-3000 is a compact mixer with high efficiency and multiple functions. It integrates the design principle of mixing and shaking with intelligent operation and can be applied to a variety of mixing and vortex shaking operations. It can not only mix various microvolume tubes, PCR plates, deep hole plates, microplates, and other common laboratory supplies, but also perform the function of vortexing all kinds of tubes. Unique design principles, which combine mixing and shaking with intelligent operation, make the operation simpler, safer, and more convenient.

Latest Ergonomic Features:

The excellent radius and dimensional technology blended with adjustable mixing speed ensure fast and perfect experiments.

3-in-1 format:


Plates

Tubes

Vortexing numerous 

tube formats

PCR Plates (skirted, semi-skirted, unskirted)

0.2 ml PCR tubes and PCR strips

 

384 hole PCR plate

0.5 ml Micro-test tube

 

96- and 384- deepwell plates

1.5 ml Micro-test tube

 

MTPs, enzyme labelled plate

2.0 ml Micro-test tube

 

Technical Data:

  • Speed Range : 300~3000 rpm
  • Touch Vortex Speed : 3500rpm
  • Shaking Orbit : 3mm
  • Time Range : 1s~99h59min or continuous / touch vortex
  • Working Noise : <50dB
  • Voltage : AC 100 ~230V, 50/60Hz
  • Power : 45W
  • Fuse : 250V, 1A, Ф5×20
  • Dimension (W*D*H) : 196 x 270 x 170mm
  • Net Weight : 7.7kgs

                  

 Three tube-stands Configured:

1 MIX-A –  96x 0.2ml tube stand. Applied to 0.2ml PCR tubes, PCR strips and 96-well PCR plates (semi-skirted and un-skirted)

 2 MIX-B-  24×0.5 ml Tube stand

 3 MIX-C –  24×1.5/2.0ml Tube stand

Remarks 96– well skirted PCR plates, 384-well PCR plates, deep-well plates can be directly put into the mixer without stand support.

Applications:

Controllable and fast mixing makes good experimental conditions uniformity between the hole and hole / tube and tube. The reproducibility is improved.           

  1. Preparation of PCR reaction system
  2. Precipitation suspension (such as bacteria, DNA, cell culture precipitation)
  3. Incubation (ELISA enzyme immunoassay analyzer)
  4. Protein staining quantitative (such as Bradford, Lowry, BCA)
  5. Report gene assays (such asβ-galactosidase, luciferase analysis)
  6. Premixed reaction system
  7. Mixing various kind of tubes